Solar module
Solar tracker
·“T” Solar Tracking System
·“V” Solar Tracking System
·BRE-T-03D
·BRE-T-03S
·BRE-T-10D
·BRE-T-10S
·BRE-T-20D
·BRE-T-20S
·BRE-T-30D
·BRE-T-30S
·BRE-T-40D
·BRE-T-40S
·BRE-V-50D
·BRE-V-50S
·BRE-V-60D
·BRE-V-110D
solar system
slew driver
 
 
 
Solar module  
“T” Solar Tracking System

Tracking system Main Performance Data

Type BRE-T-03S
BRE-T-03D
BRE-T-10S
BRE-T-10D
BRE-T-20S
BRE-T-20D
BRE-T-30S
BRE-T-30D
BRE-T-60S
BRE-T-60D
BRE-T-50S
BRE-T-50D
BRE-T-80S
BRE-T-80D
BRE-T-100S
BRE-T-100D
Structure material Hot dipped galvanized steel
Peak power generation 300Wp 1KWp 12KWp 3KWp 6KWp 5KWp 8KWp 11KWp
Max surface of total modules 2.55m² 7.66m² 15.32m² 22.98m² 45.5m² 40.85m² 61.28m² 84.27m²
Tracking technology Micro-computer control astronomical program
Wind protection system Programmable;automatic horizontal positioning at wind speeds greater than 70 km/h(43mil/h)
Tracker height 2.11m 2.93m 3.66m 5.24m 6.82m 6.82m 6.82m 8.43m
Tracker weight 113kg/
120kg
279kg/
300kg
509kg/
529kg
739kg/
729kg
1570kg/
1620kg
1460kg/
1480kg
2188kg 3370kg
Foundation 0.4m³ 1.5m³ 3.2m³ 6.3m³ 6.3m³ 6.3m³ 6.3m³ 13m³
Tracking Axes 1a×es
2a×es
1a×es
2a×es
1a×es
2a×es
1a×es
2a×es
1a×es
2a×es
1a×es
2a×es
2a×es 2a×es
Angles of rotation Vertical:0°to60°
Azimuth rotation Cogged crown wheel,activated by computer and driven by electric motor and planetary gear reducer
Vertical rotation Linear actuator activated by computer and motor
Power supply to motors 24V DC/220V,depending on location(u.s.,Europe,etc.)
Power usage of motors 10kWh/year 20kWh/year 30kWh/year
Automation Independent computer on each tracher with possible interconnection and remote control(optonal)
Anti- theft system Alarm and message byGSM upon module disconnection(optional)
Monitoring On site or remote monitoring on power output,tracking status(optiona)and tracking control(optiona)
Inverters Very flesible inverter configureations ,ranging from several per tracker to large centralized in
Wind loat Maximum rated wind speed is 145km/h(90mil/h)

Main characteristics:

  • Dual-axle tracking system for paner areas 0 through 60 m²
  • Solar tracking extremely low energy cost
  • Ground and building mounting
  • Can be mounted up to 25 m on buildings (wind load zone1)
  • About 45% increased energy output annually over fixed installation system
  • Wind and sunlight sensors
  • Integrated ligh guard
  • Track-back programming and clouding-optimized operation
  • All-weather(suitable for harsh environmental conditions:windy,stormy,snowy,dust storm etc.)
  • Programmed to retum to East facing starting position after daily tracking
  • Easy-to-assemble construction
  • Compact packageing
  • Need one-year maintenance interval